1、1.SCOPE 范围1.1.To ensure correct maintenance of water preparation systems and continuous production of PW/WFI quality water. 保证水制备系统的正常维护,持续生产符合 PW/WFI 要求的水。2.DEFINITIONS 定义2.1.PW USP Purified Water PW符合美国药典的纯水2.2.WFI USP Water for Injection WFI符合美国药典的注射用水3.REFERENCES 参考参考 3.1.United States Pharmacop
2、eia , current revision 美国药典,当前版本3.2 PW/WFI System Manual PW/WFI 系统使用手册4.RESPONSIBILITY - Maintenance/Engineering, QA 职责维护、工程、QA 人员5.ATTACHMENTS 附录附录5.1.MF-01-0001-01: PW/WFI System Daily Maintenance Check MF-01-0001-01: PW/WFI 系统日常维护检查5.2.MF-01-0001-02: Maintenance Record of PW System MF-01-0001-02:
3、 PW 系统维护记录5.3.MF-01-0001-03: Maintenance Record of WFI System MF-01-0001-03: WFI 系统维护记录6.PROCEDURES 程序6.1.Maintenance of Pumps 泵的维护6.1.1.The radiator of the pump motor, the cover and the shaft of cooling fan shall be checked daily. Please replace when any damage occurs. 泵电机散热片,冷却风扇盖板和叶片应保持完整,如有损坏应立即
4、更换。6.1.2.The pump shall be cleaned daily. 泵应每日保持清洁。 6.1.3.The operation of motor bearing and shaft shall be checked by rob every day. Any abnormity shall be treated immediately. 泵的电机轴及轴承应每天用听棒检查运行声响,任何异常情况都应及时处理。 6.1.4.The oiling point shall be lubricated with high temperature grease once a year. 各加
5、油点应定期(每年)补充高温润滑油脂。6.2.Contamination and Cleaning of RO Film 反渗透膜的使用及清洗6.2.1.First Use of RO Film: 新反渗透膜的初次使用The RO Film is kept in sealed plastic bags with storage mixture of 1% sodium bisulflate and 20% hydroxy-pyruvate. The bags shall have no damage before it is opened in time of installation. The
6、 film shall be put into film tube as soon as it is opened and could be used after cleaning. 反渗透膜保存在密封的塑料袋中,袋内为 1%亚硫酸氢钠和 20%羟基丙脂的混合液。在安装前 袋子应完整无损。拆封后应马上放入膜管内,清洗后即可使用。6.2.2.There may be some Residual material on the RO film after long time operation of pure water. The reasons could be ineffective pre-
7、treatment, improper control, polluted inlet water or wrong chemicals. The RO film must be cleaned in the following procedures: 由于净水长时间在 RO 膜上运行,RO 膜上会结垢。结垢的原因有:预处理系统失效,控制不当, 进水污染或使用错误的化学品。RO 膜按下列程序清洗:6.2.2.1.Prepare suitable cleaning solution with correct pH value per section 6.2.5. Be sure that all
8、 chemicals in the solution have been fully dissolved and evenly mixed to be transparent and clear solution before it is filled into the film. 准备适当的清洗液,准确的 PH 值依照 6.2.5 节.在加入清洗液之前,确认所有的化学 品已完全溶解混合均匀。6.2.2.2. The solution is filled into the film tube by low pressure and flow of pump. The pressure shal
9、l be low enough that no osmosis happens. The cleaning solution shall be first discharged and then circulated. 用泵的低压流量打入膜管,低压控制在无渗透液产生.清洗液先排放后循环。6.2.2.3. The acid will be consumed when it dissolves the inorganic sediment and its pH value shall rise by 0.5 unit. Add acid at that time until the pH valu
10、e drops by 0.5. 当酸溶解无机物沉淀时酸会消耗,PH 值升高 0.5 个单位时,需加酸直到 PH 值下降 0.5 个单位。6.2.2.4. Dipping: Shut off the pump. Dip the components in the solution for 1 hour or longer for dirt difficult to dissolve. 浸泡:关掉泵.将元件浸泡在溶液中 1 小时,如有难溶污垢可延长浸泡时间。6.2.2.5. High-speed Flushing: High-speed water flow in about 30 to 40 m
11、inutes will clear the dirt on the surface of the film. 高速冲洗:用高速水流冲洗 30 到 40 分钟,将膜表面污垢冲洗出去。6.2.2.6. The used solution will be discharged and sampled to compare with pure solution for analysis of the cleaning effect. 排除清洗液,取样与原液分析比较,确认清洗效果。6.2.2.7. The flushing water shall be purified water in tempera
12、ture of at least 20C. The cleaning solution in the film must be cleared before normal operation of the system. 用不低于 20C 的纯化水冲洗,在正常操作之前必须把膜内清洗液冲掉。6.2.2.8. Clean Again: The film shall be flushed by purified water in at least 10 minutes. Normal production can begin only after it is rinsed clean. 再清洗:用纯
13、化水冲洗膜至少 10 分钟.冲洗干净后才能开始正常的生产。6.2.3.Contamination of Reverse Osmosis Film Module 反渗透膜污染6.2.3.1. After a period of normal operation, the complex polyamide reverse osmosis film module could be contaminated by some suspends or matters difficult to dissolve in water supply such as calcium carbonate, calc
14、ium sulfate, metal oxide, silicon sediment, organic or inorganic sediments. 运行一段时期后,复合反渗透膜会受到水中悬浮物和难溶物的污染,如碳酸钙,硫 酸钙,金属氧化物,硅沉积,无机物和有机物沉积物。The character of pollutant and contaminating speed depends on the quality of the water supply. The contamination can happen quickly and needs to be monitored becau
15、se the film module can be damaged in a short period of time. 污染物的性 质及污染速度与给水有关.污染发生很快需监控,因为污染会在很短的一段时间损坏 膜。6.2.4.Elimination of Pollutant 污染物的去除The pollutant can be eliminated either chemically or physically. Therefore, the RO system shall be cleaned after daily operation in physical way of low pres
16、sure operation for 15 minutes in order to get rid of the surface dirt. But chemical cleaning must be done if any of the following happens: 污染物能够用化学或物理的方法去除.因此,RO 系统每天运行后可以用物理冲洗的方法去除膜 表面的沉积物。6.2.4.1. The flow reduces by 10% of the normal flow even in normal pressure and temperature. 在正常的压力和温度下流量降低正常值
17、的 10%。6.2.4.2. The conductivity of the produced water has been more than double of the original conductivity in condition that the working pressure and inlet conductivity remains the same. 在原水电导率和工作压力不变时,产品水电导率超过初期两倍时。6.2.4.3. The difference of working pressure and the concentrated water has been mo
18、re than double of the original value. 工作压力和浓缩水超过初期两倍时。6.2.4.4. The system has been stopped for a long time and needs to be sealed. 系统长时间停用需要封存。6.2.5.Cleaning Agent of the Reverse Osmosis Film Module 反渗透组件清洗剂Several varied cleaning agents are prepared for pollutants of different reasons. Listed below
19、 are some agents often used: 根据不同的原因配制了不同的清洗剂.常用的清洗剂见下表:No.Cleaning AgentFilling Quantity in Preparation of 30L SolutionPH Regulation1Citric Acid 柠檬酸 RO Production Water 反渗透产品水60g30LUse NH4OH For PH=4.0 用氨水调节至 pH 值为 42STPP 三聚磷酸钠 EDIT Sodium Tetra-60g Use H2SO4 For PH=10.0 hydrochloride EDIT 四钠盐 RO P
20、roduction Water 反渗透产品水30g30L用硫酸调节至 pH 值为 10.03STPP 三聚磷酸钠 Emulsifier ABSCa 十二烧基苯磺酸钠 RO Production Water 反渗透产品水60g30g30LUse H2SO4 For PH=10.0 用硫酸调节至 pH 值为 10430% H2O2 30%的双氧水 RO Production Water 反渗透产品水0.2LAdd to 30L 加至 30 升Use NH4OH For PH=4.0 用氨水调节至 pH 值为 4Choose the best cleaning agent after chemica
21、l analysis has been done on the pollutant and careful comparison of the results. The ordinary choice is as follows: 对污染物分析和比较分析结果,选择最好的清洗剂。一般选择见下表:Pollutant 污染物污染物Common Phenomenon 常见现象常见现象Treatment 处理方法处理方法Calcium or Magnesium Sediment (CaCO3Ca2P04) 钙镁沉积物Distinct Reduce of Desalination; 脱盐率明显下降 Inc
22、rease of System Pressure Drop; 系统压降增加 Lower Water Production 系统产水量稍降Use 1# Cleaning Agent 用 1 号清洗液Oxide (iron, nickel, copper, etc.) 氧化物 (铁、镍、铜等)Distinct Reduce of Desalination; 脱盐率明显下降 Distinct Increase of System Pressure Drop; 系统压降明显升高 Much Lower Water Production 系统产水量明显降低Use 1# Cleaning Agent 用 1
23、 号清洗液Various Colloid (iron, organic matters and colloid) 各种胶体 (铁、有机体及胶体)Some Reduce of Desalination; 脱盐率稍有降低 Steady Increase of System Pressure Drop; 系统压降渐上升 Steadily Lower Water Production 系统产水量逐渐减少Use 2# Cleaning Agent 用 2 号清洗液Calcium Sulfate 硫酸钙Distinct Reduce of Desalination; 脱盐率明显下降 Some Increa
24、se of System Pressure Drop; 系统压降稍有适度增加 Steadily Lower Water Production 系统产水量稍有降低Use 2# Cleaning Agent 用 2 号清洗液Organic Dirt 有机物沉积Possible Reduce of Desalination; 脱盐率可能降低 Steady Increase of System Pressure Drop; 系统压降逐渐升高 Steadily Lower Water Production 系统产水量逐渐降低Normally Use 2# Cleaning Agent but 3# fo