EL屏幕软件升级.ppt
《EL屏幕软件升级.ppt》由会员分享,可在线阅读,更多相关《EL屏幕软件升级.ppt(34页珍藏版)》请在得力文库 - 分享文档赚钱的网站上搜索。
1、25.05.08Seite 2OL81/DIG000/DM4000Training overview :Interface structureHow to Start-up the new components 1. OP1000 (applicationsoftware) 2. DIG000 (applicationsoftware) 25.05.08Seite 3DIG000 with MasterLogic and OP1000 NetworkEthernetCan Group 07with other sensorsOL80FR.Fx.FE.Network 1DIG000 Softwa
2、re: Pc0016-8003M +Application software xxx.xxxPossible communicationsMitshubishiSiemensBeckhoff.Standard Ethernet: Software Pc0016-8002M Ethernet Ip Software Pc0016-8010M EGDOP 1000PLCEthernet SwitchX8; 24V DC (z.B. 326491) Can Group 07with other sensorsOL80FR.Fx.FE.Network 2DIG000DIG00025.05.08Seit
3、e 4How to Start-up the new componentsChange the PC-Ethernet settingsDownload Software to the DIG000Set the ip-address of the OP1000 PanelDownload software to the OP1000 PanelDownload PLC-software in DIG000Check the Dongle Value EK 5101 25.05.08Seite 5How to Start-up the new components1. Change the P
4、C-Ethernet settingsTo get a ethernet connection between two devices you need a few conditionsA ethernet connection exists of following parts. ip-address010.006.002.003Netmask255.255.000.000Gateway000.000.000.000Device 1ip-address010.006.002.124Netmask255.255.000.000Gateway000.000.000.000Device 2A co
5、nnection is only possible if the blue numbers are the same25.05.08Seite 6How to Start-up the new components1. Change the Pc-Ethernet settingsOpen the networksetting in your PC10 . 6 . 2 . 4To get a connection to the devicesSet the ip-address of the pc-ethernet cardTo a address like 10.6.x.xAttention
6、:If you connect a Pc direkt to a device you Need a cross-cabel.If the Pc and the devices are connected Over a ethernet switch you need a patch cabel.25.05.08Seite 7How to Start-up the new components1. Change the Pc-Ethernet settingsPut in the ip-addressOf the DiG000Open javacanmonpress the Add butto
7、n25.05.08Seite 8How to Start-up the new components1. Change the Pc-Ethernet settingsIf you dont know the ethernet address you have to set or read the ip-address1. With a seriell connection2. with Javacanmon Can-Dongle. recommended25.05.08Seite 9How to Start-up the new components1. Change the Pc-Ethe
8、rnet settingsChange to service,Select the Service functionSet TcpIp Addr andPress the buttonSet25.05.08Seite 10How to Start-up the new components1. Change the Pc-Ethernet settingsConnect the hardware to the PC.Ethernet (Cross cabel) z.B. 328927 (10m) 25.05.08Seite 11How to Start-up the new component
9、s1. Change the Pc-Ethernet settingsHere you see theActive connectionTo the hardware25.05.08Seite 12How to Start-up the new components2. Download software to the DIG000 or DM4000Basicsoftware: PC0016-8008M_ZBBasis MasterLogic: PC0016-8003M_ZDEhternet/IP: PC0016-8002M_ZCPress the Download buttonChange
10、 to Software25.05.08Seite 13How to Start-up the new components2. Download software to the DIG000 or DM4000Select the software and press openDownload is onlyPossible over Ethernet 25.05.08Seite 14How to Start-up the new components3. Set the Ip-address of the OP1000 PanelIf you press with your fingers
11、 at the same time these points for At least 2s. The panel switch to the setup mode25.05.08Seite 15How to Start-up the new componentsChange with the keyboard to the function CONFIG and press ENTERThe panel switch to the configuration mode3. Set the ip-address of the PanelENTER25.05.08Seite 16How to S